E-Stim Emporium Knowlegebase
Knowledge is power, power is useful when you are stimming
  • Home
  • Instructions
    • Conductive Rubber Loop Electrodes
    • Bipolar Nipple Play Electrodes
    • Saddle Electrodes
    • Constrictor Wire Cored Conductive Rubber Electrode
    • E-Stim Emporium
    • E-Stim Systems (aff)
    • Electrastim (aff)
  1. You are here:  
  2. Home
  3. Instructions

Insulated Conductive Rubber Loop Electrode Instructions

Product applicability

Product Type Insulated Conductive Rubber Loop Electrodes
SKU Codes Generic

Materials And Design

These insulator and conductive rubber loop combinations are made from several body-safe materials. The plastic insulator bodies are made from PLA or vapour-smoothed ABS depending on the model. The conductive rubber loops are made from high-quality British conductive rubber.

Conductive rubber (a silicone elastomer) is created with carbon particles suspended within the silicone blend; this carbon element turns silicone into conductive silicone. In use, some black residue may be seen on your fingers or other body parts; this is normal and a result of outer layers of carbon shedding due to stretching and flexing.

The plastic insulators are used to better control the current flow and isolate nerve groups such as the dorsal nerve, allowing you to create interesting current paths.

General Safety Considerations

DO NOT CONNECT ANY ELECTRICAL DEVICE TO ANY LOCATION ABOVE THE WAIST (ACROSS THE ARMS COUNTS AS ABOVE THE WAIST!), BUT ESPECIALLY DO NOT CONNECT ACROSS THE HEART (FRONT TO BACK, OR SIDE TO SIDE), CHEST, NECK OR HEAD. DO NOT USE IF FITTED WITH A PACEMAKER OR OTHER ELECTRONIC MEDICAL IMPLANT, ARE EPILEPTIC OR ARE OR MAYBE PREGNANT. REMEMBER YOU USE THIS DEVICE AT YOUR OWN RISK.

Instructions For Use

Fitting

You must ensure that your control box is switched off and power level knobs are set to their minimum position before fitting electrodes! A second electrode will need to be used to create a circuit when using a monopole electrode.

  1. Attach one of your channel plugs to one end of the conductive rubber tubing. Note: Only fit one plug from a channel into each electrode, or you will create a short. This will mean you do not feel anything. You also risk damaging your control box if you create a short in this way.
  2. Apply conductive gel/lube to the contact surfaces touching your skin.
  3. Slide the loop into place and adjust the conductive rubber to achieve a snug fit. If needed, apply extra conductive gel during your session.
  4. Turn on your control box and adjust your controls.
  5. Enjoy and adjust the fit of your electrode during the session if required.

 Removal

  1. Ensure the output of your control box is set to zero, and ideally, switch off the control box before removing your electrodes.
  2. Unplug your cable, loosen your electrode and remove it.
  3. Wipe down the electrode to remove excess conductive gel.

Cleaning

Wash in warm, soapy water and dry the electrode before storing it until your next session. The conductive rubber can be removed to aid cleaning, but when refitting it, use a push-pull action to minimise stretching of the conductive rubber. Do not use abrasive or caustic materials on the conductive rubber or plastic components.

Nipple Clamp Electrodes

Product applicability

Product Type Bi-Polar Nipple Clamp Electrodes
SKU Codes A1x1 etc

Materials And Design

These nipple clamp electrode combinations are made from several body-safe materials. The plastic insulator bodies are made from PLA or vapour-smoothed ABS, depending on the model. The conductive rubber loops are made from high-quality British conductive rubber.

Conductive rubber (a silicone elastomer) is created with carbon particles suspended within the silicone blend; this carbon element turns silicone into conductive silicone. In use, some black residue may be seen on your fingers or other body parts; this is normal and a result of outer layers of carbon shedding due to stretching and flexing.

The plastic insulators create the clamping effect while the conductive rubber acts as the electrode surfaces.

General And Nipple Play Safety Considerations

GENERAL E-STIM SAFETY - DO NOT CONNECT ANY ELECTRICAL DEVICE TO ANY LOCATION ABOVE THE WAIST (ACROSS THE ARMS COUNTS AS ABOVE THE WAIST!), BUT ESPECIALLY DO NOT CONNECT ACROSS THE HEART (FRONT TO BACK, OR SIDE TO SIDE), CHEST, NECK OR HEAD. DO NOT USE IF FITTED WITH A PACEMAKER OR OTHER ELECTRONIC MEDICAL IMPLANT, ARE EPILEPTIC OR ARE OR MAYBE PREGNANT. REMEMBER YOU USE THIS DEVICE AT YOUR OWN RISK.

NIPPLE PLAY SAFETY - ONLY USE BIPOLAR NIPPLE ELECTRODES AND ONLY USE ONE CHANNEL PER NIPPLE USING A CONTROL BOX WITH ISOLATED CHANNELS. IF YOU DO NOT KNOW IF YOUR CONTROL BOX HAS ISOLATED CHANNELS, ONLY STIM ONE NIPPLE. YOU CAN USE TWO CONTROL BOXES FOR DOUBLE NIPPLE PLAY.

NIPPLE PLAY SHOULD ONLY BE CONDUCTED BY PEOPLE WHO KNOW THE RISKS, KNOW THEIR EQUIPMENT AND ONLY USE ONE CHANNEL PER NIPPLE FROM AN ISOLATED CONTROL BOX.

NIPPLE STIMMING IS EDGE PLAY AND SHOULD BE TREATED AS SUCH.

Instructions For Use

Fitting

You must ensure that your control box is switched off and power level knobs are set to their minimum position before fitting electrodes! Only use one channel per nipple and place electrodes as close to the nipple as possible.

  1. Connect your cable plugs (one channel) to each electrode surface in your clamp or to each pad if you are using pads with one channel per nipple.
  2. Apply conductive gel/lube to the contact surfaces touching your skin; this is not needed for self-adhesive electrode designs.
  3. Fit the electrode pads or clamp into place and tighten to secure it in place if using a clamp.
  4. Turn on your control box and adjust your controls.
  5. Enjoy and adjust the fit of your electrode during the session if required.

 Removal

  1. Ensure the output of your control box is set to zero, and ideally, switch off the control box before removing your electrodes.
  2. Unplug your cable, loosen your electrode and remove it.
  3. Wipe down the electrode to remove excess conductive gel. If using self-adhesive electrodes, place them back on their plastic backing sheet.

Cleaning

Wash in warm, soapy water and dry the electrode before storing it until your next session. The conductive rubber can be removed to aid cleaning, but when refitting it, use a push-pull action to minimise stretching of the conductive rubber. Do not use abrasive or caustic materials on the conductive rubber or plastic components.

Stainless Steel Saddle Electrodes

Product applicability

Product Type Stainless Steel Monopole Electrodes
SKU Codes Saddle, SaddleXL, V2 Saddle

Materials And Design

These monopole electrodes are made from 3D-printed 316L Stainless Steel.

This process allows us to create impossible shapes using any other manufacturing technique.

Each electrode has a stretch, non-slip velcro strap to secure it.

The Saddle electrodes have multiple ways to connect to them, and they can be used as a common electrode in a tri-phase configuration, but ensure that both plugs from a channel are not plugged into the same electrode, as that can cause a short and possibly damage your e-stim control box.

General And Nipple Play Safety Considerations

DO NOT CONNECT ANY ELECTRICAL DEVICE TO ANY LOCATION ABOVE THE WAIST (ACROSS THE ARMS COUNTS AS ABOVE THE WAIST!), BUT ESPECIALLY DO NOT CONNECT ACROSS THE HEART (FRONT TO BACK, OR SIDE TO SIDE), CHEST, NECK OR HEAD. DO NOT USE IF FITTED WITH A PACEMAKER OR OTHER ELECTRONIC MEDICAL IMPLANT, ARE EPILEPTIC OR ARE OR MAYBE PREGNANT. REMEMBER YOU USE THIS DEVICE AT YOUR OWN RISK.

Instructions For Use

Fitting

You must ensure that your control box is switched off and power level knobs are set to their minimum position before fitting electrodes! The saddle electrodes are monopole electrodes, meaning you must use them with another electrode to complete a circuit.

Each saddle has four connection options. The centre area on the top side features two mushroom heads that can be connected to 3.5mm snap connectors. The front and rear regions connect to 2mm pins or 4mm plugs. Lastly, on the top side, there are loops for connecting crocodile clips.

  1. Connect one of your cables plugs to your saddle and the other to a separate electrode.
  2. Apply conductive gel/lube to the underside contact surface that touches your skin.
  3. Fit the electrodes in place. The elasticated strap can hold the saddle in place. On the regular saddle, the strap sits on top of the four metal loops, and when tightened, it deforms between them, effectively holding the strap in place. In the V2 version, the strap fits under the two arms on top of the electrode.
  4. Turn on your control box and adjust your controls.
  5. Enjoy and adjust the fit of your electrode during the session if required.

 Removal

  1. Ensure the output of your control box is set to zero, and ideally, switch off the control box before removing your electrodes.
  2. Unplug your cable, loosen your electrode strap and remove it.
  3. Wipe down the electrode to remove excess conductive gel. Clean before storing for the next session.

Cleaning

Wash the electrode in warm, soapy water and dry it before storing it until your next session. Do not use abrasive or caustic materials on the conductive rubber components.

  1. Constrictor Monopole Electrode Instructions

Page 1 of 2

  • 1
  • 2
E-Stim Emporium
This site uses affiliate links; these are labelled (aff). An affiliate link is a special web link that allows someone to earn a commission for promoting a product or service. When someone clicks on an affiliate link and buys something, the person who shared the link earns a percentage of the sale. Buying something through an affiliate link does not affect the price you pay.